How to replace an AO Smith lower thermostat (quick overview):

  1. Turn off power at the circuit breaker and confirm it’s off with a voltage tester
  2. Remove the lower access panel, insulation, and plastic protector
  3. Mark and disconnect the wires from the old thermostat
  4. Snap out the old thermostat and install the new one — it must sit flush against the tank
  5. Reconnect the wires, set the temperature to 120°F, and reassemble
  6. Restore power and check water temperature after about two hours

The lower thermostat controls the bottom heating element in a dual-element electric water heater. When it fails, you’ll notice lukewarm water, no hot water at all, or wildly inconsistent temperatures. The good news: the part typically costs under $25, and the repair takes under an hour.

That said, working near live electrical components and a pressurized water tank carries real risk. If anything feels unclear at any point, stop and call a licensed plumber.

I’m Ben Smith, a digital marketing and home services growth strategist with over 25 years of experience helping homeowners connect with the right repair solutions — including common repairs like ao smith lower thermostat replacement. In this guide, I’ll walk you through everything you need to know to diagnose the problem, choose the right part, and complete the repair safely.

Infographic showing how AO Smith electric water heater elements and thermostats work together step by step infographic

Simple guide to ao smith lower thermostat replacement terms:

Understanding Your AO Smith Lower Thermostat

To understand why a lower thermostat fails—and how to fix it—we first have to look at how dual-element electric water heaters operate. Most residential electric water heaters feature two heating elements: one at the top (upper) and one at the bottom (lower).

These elements do not run at the same time. Instead, they work in a coordinated relay:

  1. When the tank is cold, the upper thermostat takes priority, heating the top portion of the tank first so you get hot water quickly.
  2. Once the upper portion of the tank reaches its target temperature, the upper thermostat switches power down to the lower thermostat.
  3. The lower thermostat then cycles the lower element on to heat the remaining water in the bottom of the tank.

Because the lower element is responsible for maintaining the overall temperature of the bulk of the water, the lower thermostat works much harder than its upper counterpart. It cycles on and off repeatedly throughout the day as cold water enters the bottom of the tank.

To help visualize the differences between these two essential components, we have put together this quick-reference comparison table:

Feature Upper Thermostat Lower Thermostat
Primary Function Prioritizes rapid heating of top tank water; controls power switching. Maintains bulk water temperature in the bottom of the tank.
High-Limit ECO Switch Yes (Red reset button to prevent overheating above 180°F). No (Relies on the upper thermostat’s ECO for emergency shutoff).
Wiring Complexity High (Typically has 4 terminal screws for power routing). Low (Typically has 2 terminal screws for simple on/off control).
Typical Failure Symptom Completely cold water (upper element never turns on). Lukewarm water (only the top of the tank gets heated).

Understanding the AO Smith Lower Thermostat Replacement Part 100110039

When sourcing a replacement, you will frequently come across the A.O. Smith 100110039 Lower Thermostat. This is a genuine, factory-authorized OEM (Original Equipment Manufacturer) part designed specifically for dual-element electric water heaters.

This specific lower thermostat is rated for adjustable temperature ranges from 90°F to 150°F. Genuine parts like this are typically priced around $19.95 to $23.99 and are highly recommended over cheap, knock-off alternatives.

Another common OEM part number you might encounter for slightly different models is the AO Smith 100108422 Lower Electric Water Heater Thermostat, which replaces the older part number 9000507045. These thermostats feature a bimetal sensor design that reacts directly to the temperature of the steel tank wall. They are built to handle standard residential voltages (208V, 240V, 277V, or 480V) and ensure your system operates safely.

Upper vs. Lower Thermostats: Key Differences

Can you swap them? This is one of the most common questions we receive.

The short answer is no, you cannot use a lower thermostat in place of an upper thermostat. The upper thermostat contains the Emergency Cut-Off (ECO) high-limit safety switch. This is the red button that trips and cuts all power to the water heater if the water temperature exceeds a dangerous 180°F. Because a lower thermostat lacks this ECO switch, using it at the top would create a severe safety hazard.

However, in rare cases involving single-element water heaters (which only have one element located at the bottom), an upper-style thermostat is actually used to control that single element because the system still requires a high-limit safety switch. For standard dual-element systems, always replace a lower thermostat with a dedicated lower thermostat, and an upper with an upper.

Signs You Need an AO Smith Lower Thermostat Replacement

Using a multimeter to test a water heater thermostat

How do you know the lower thermostat is actually the culprit? Before you roll up your sleeves, it helps to run through a few diagnostic checks. Many water heater issues can stem from a variety of sources, which we cover in our guide on Common Water Heater Problems and How to Solve Them.

Common Symptoms of a Faulty Lower Thermostat

If your lower thermostat has failed, your water heater will usually exhibit one of the following warning signs:

  • Lukewarm Water: If the upper element is working but the lower element is not, you will only get a few minutes of hot water before it turns lukewarm. This is because only the top quarter of the tank is being heated.
  • Scalding Hot Water: If the bimetal sensor inside the lower thermostat fails in the “closed” position, it will keep sending power to the lower element continuously, resulting in dangerously hot, scalding water.
  • Frequent Temperature Fluctuations: A failing thermostat may struggle to accurately measure the tank temperature, leading to erratic cycles where the water is hot one hour and cold the next.
  • No Hot Water at All: If the lower thermostat shorts out or fails in a way that prevents the electrical circuit from completing, it can trip the main circuit breaker or the upper thermostat’s ECO switch, shutting down the entire unit.

If you suspect a failure, you can test the thermostat using a multimeter. With the power completely disconnected, check for continuity across the terminals. If the water in the tank is cold and there is no continuity, the thermostat is defective and must be replaced.

How to Choose the Correct Replacement Thermostat

Choosing the right part ensures your water heater runs efficiently and maintains its warranty. While universal thermostats are widely available at home improvement stores, we always recommend using genuine OEM parts.

Using non-OEM parts can sometimes lead to poor physical contact with the tank, inaccurate temperature readings, or premature failure. To ensure you are getting the right part, you can Order OEM Parts for Water Heaters directly through official A.O. Smith channels or authorized distributors.

Finding Your Model and Serial Number

To find the exact replacement thermostat for your unit, you will need your water heater’s model and serial number. This information is printed on the rating plate located on the side of the water heater tank.

A close-up of a water heater rating plate showing model and serial numbers

Once you have these numbers:

  1. Go to the manufacturer’s parts lookup tool.
  2. Enter your serial number to find the exact part numbers approved for your unit.
  3. Check if your water heater is a single-element or dual-element model.

If you want to understand the inner workings of your system more thoroughly before diving in, check out The Easy Fix Hot Water Heater Manual for a complete breakdown of electric tank components.

Step-by-Step Guide to AO Smith Lower Thermostat Replacement

Ready to tackle the replacement? This is a highly manageable DIY project if you follow the correct safety protocols. For official reference, you can also consult the guide on how to Replace the Thermostat – A. O. Smith Water Heaters at Lowes.

Step 1: Safety First and Power Disconnection

WARNING: Electric water heaters typically run on 240 volts. This level of electricity is extremely dangerous.

  1. Go to your home’s main electrical service panel (circuit breaker box).
  2. Locate the double-pole breaker labeled “Water Heater” and flip it to the OFF position.
  3. Head back to the water heater. Remove the lower access panel screw and pull off the metal cover.
  4. Carefully fold back the fiberglass insulation.
  5. CRITICAL STEP: Use a non-contact voltage tester to check all wires leading to the thermostat. Ensure the tester does not light up or beep. Do not touch any terminals until you have verified the power is completely off.
  6. Put on protective gloves to shield your hands from sharp metal edges around the access port.

Step 2: Accessing and Removing the Old Thermostat

  1. Remove the clear plastic protective cover clipping over the thermostat.
  2. Take a quick photo of the wiring with your phone. This will serve as your wiring diagram during reassembly.
  3. Using a screwdriver, loosen the terminal screws and carefully disconnect the wires.
  4. Gently pry the plastic tabs of the mounting bracket outward.
  5. Slide the old thermostat upward and out of the metal mounting clip. Be careful not to bend the mounting bracket.

Step 3: Installing Your AO Smith Lower Thermostat Replacement

  1. Take the new thermostat and slide it down into the mounting bracket until it snaps securely into place.
  2. The Business Card Test: The bimetal sensor on the back of the thermostat must make direct, tight contact with the curved metal surface of the water tank. To verify this, try to slide a standard business card between the back of the thermostat and the tank. If the card slips in, the thermostat is not making proper contact. You must adjust or tighten the mounting bracket until no gap exists. Poor contact will cause the thermostat to read temperatures incorrectly, leading to overheating or constant cycling.

Step 4: Rewiring, Temperature Calibration, and Power Restoration

  1. Refer to the photo you took in Step 2. Reconnect the wires to their respective terminals and tighten the screws firmly. Loose connections can cause electrical resistance, generating heat that can melt the plastic casing or trip the breaker.
  2. Set the temperature dial on the new thermostat. We strongly recommend setting it to 120°F (the factory standard). This setting provides plenty of hot water for household needs while drastically reducing the risk of scalding and saving energy.
  3. Reinstall the plastic protective cover.
  4. Replace the fiberglass insulation, making sure it covers the thermostat area completely without being packed too tightly.
  5. Reattach the outer metal access panel and secure it with the screw.
  6. Head back to your breaker panel and flip the circuit breaker back ON.

Frequently Asked Questions about AO Smith Thermostats

What temperature should my AO Smith thermostat be set to?

We recommend setting both the upper and lower thermostats to 120°F (49°C). According to the ASSE 1070 plumbing standard, this is the optimal temperature to prevent rapid scalding (water at 140°F can cause third-degree burns in less than 5 seconds).

Additionally, keeping your water heater at 120°F reduces standby heat loss, saving you money on your monthly utility bills. If you struggle with smelly water caused by bacterial growth in hard water areas, a temporary increase to 140°F can kill the bacteria, but point-of-use mixing valves should be installed to prevent burns at the tap.

How long does it take for water to heat up after replacing the thermostat?

After you turn the power back on, it typically takes between 1 to 2 hours for a standard 50-gallon electric water heater to fully heat the water. The upper element will heat the top of the tank first, so you might get a small amount of hot water within 30 minutes, but the lower thermostat won’t finish heating the entire tank until the full cycle is complete.

Can I use an upper thermostat in place of a lower thermostat?

In a dual-element water heater, you should never use an upper thermostat in the lower position. The upper thermostat has extra terminals designed to switch power between the two elements, along with a high-limit ECO safety switch. A lower thermostat only has two terminals and is designed for simple, single-stage temperature control. Installing an upper thermostat in the lower slot will result in incorrect wiring and can cause the system to malfunction.

Conclusion

Replacing a faulty lower thermostat is one of the most cost-effective ways to bring your electric water heater back to life. For a small investment in parts and less than an hour of your time, you can restore steady, reliable hot water to your home.

However, dealing with electrical wiring and high-voltage systems isn’t for everyone. If you perform the business card test and still can’t get a flush fit, or if you feel uncomfortable handling electrical components, we are always here to help.

At Plumbing Rescue, we provide rapid, professional water heater solutions across our service areas, including Austin, TX, Denver, CO, Indianapolis, IN, and Phoenix, AZ. If you prefer to have a licensed technician handle the job safely and quickly, check out our guide on how to Fix Your Tank for Less with Affordable Water Heater Repair or contact our local team directly at Plumbing Rescue Denver. We are available 24/7 to rescue your home from plumbing and hot water emergencies!

Dealing With This Yourself? Get Connected With a Local Plumber.